HomeMy WebLinkAbout204737_1_Corrections.docx PLAN CHECK NO: 10184741 PROJECT ADDRESS: 216 N Bush St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V A, SPK OCCUPANCY CLASSIFICATION(S): U, R-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/13/2015 INITIAL REVIEW 6/17/2015 EXPIRATION 10/10/2015 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Cyrus Antia 3. TEL: (310)795-4455 FAX: VALUATION: $3,000.00 EMAIL: cyrusantia@msn.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A1.2 – Detail 3: Specify 4-inch diameter maximum spacing at guard rail. 1013.4 Opening limitations. Required guards shall not have openings which allow passage of a sphere 4 inches in diameter from the walking surface to the required guard height.Sheet A1.2 – Detail 3: Revise the guard rail minimum height to 42 inches above floor. 1013.3 Height. Required guards shall not be less than 42 inches high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. On stairs, from the line connecting the leading edges of the tread nosings; and3. On ramps, from the ramp surface at the guard.Sheet A1.2 – Detail 3: Specify steel plate size and thickness between the guard rail and rim joist.Sheet A1.2 – Detail 3: Specify bolt spacing, minimum edge distance to steel plate at guard rail to rim joist connection.Sheet A1.2 – Detail 6: Specify the intended use on the second floor (loft, bonus room…etc)Sheet A1.2 – Detail 7: If the bottom edges of glazing are within 60 inches above the floor, glazing are required to be tempered. 2406.4.6 Glazing adjacent to stairs and ramps. Glazing where the bottom exposed edge of the glazing is less than 60 inches above the plane of the adjacent walking surface of stairways, landings between flights of stairs, and ramps shall be considered a hazardous location.Sheet A1.2 – Detail 8: Revise guard rail height to 42 inches minimum.