HomeMy WebLinkAbout201838_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10183820
PROJECT ADDRESS:
2649 3/4 W First St Unit# WCC03
PLAN CHECK ENGINEER:
Mazarji, ZacTEL:714
647-5831FAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
2/4/2015
INITIAL REVIEW
2/20/2015
EXPIRATION
8/3/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Christine Kim
3.
TEL:
(949)930-7462
FAX:
VALUATION:$20,000.00
EMAIL:
christine.kim.contractor@crowncastle.com
FLOOD ZONE:X-0602320257J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit 3corrected sets of plans.(When needed) Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information. If applicable please remove any and all electrical sheets.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceReference calculations from Aero Solution, LLC, Structural analysis report for existing tower,Provide as built drawings to confirm the results of structural calculations. Provide one copy existing geotechnical report to confirm values as shown in calculations.Provide as built structural drawings, (Foundation size, rebar, pole size attachment, etc.) and attach a coy to each set of drawings. As built drawings to be labeled as. “For reference only”. As built drawings to be reviewed by engineer to confirm the results of structural calculations by Aero Solution, LLC, Group.