HomeMy WebLinkAbout205184_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10184905 PROJECT ADDRESS: 1915 N Flower St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/28/2015 INITIAL REVIEW 6/29/2015 EXPIRATION 10/25/2015 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Bryan Burkhart 3. TEL: (310)704-8467 FAX: (949)631-1065 VALUATION: $1.00 EMAIL: Bryan@burkhartbros.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet 2: Roof plan indicates both roof rafter and roof truss size and spacing. If roof trusses are specified as an option, provide roof truss shop drawing or specify roof truss shop drawing to be part of a deferred submittal on the title sheet.Sheet 2: Provide hold-down detail.Sheet 2: Provide shear transfer detail between roof-diagram and gable-end wall.Sheet 2: Provide exhaust fan with minimum capability of 50 cfm in the bathroom.Sheet 2: Specify minimum clearance dimension at water closet. 2010 CPC Section 407.5 Setting. Fixtures shall be set level and in proper alignment with reference to adjacent walls. No water closet or bidet shall be set closer than fifteen (15) inches from its center to any side wall or obstruction nor closer than thirty (30) inches center to center to any similar fixture. The clear space in front of any water closet or bidet shall be not less than twelve-four (24) inches. No urinal shall be set closer than twelve (12) inches from its center to any wall or partition nor closer than twenty-four (24) inches center to center. Exception: The installation of paper dispensers or accessibility grab bars shall not be considered obstructions.Sheet 2: Specify landing and dimensions on the plan. R311.3 Floors and landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼ unit vertical in 12 units horizontal (2 percent) Exception: Exterior balconies less than 60 square feet and only accessible from a door are permitted to have a landing less than 36 inches measured in the direction of travel.Sheet 3 – Detail 2: Specify anchor bolt spacing and plate washer minimum size on detail 2.Sheet 3 – Detail 2: Specify footing depth and width.Sheet 3 – Detail 2: Specify 3 inch minimum clearance between bottom of rebar and exposed earth.Sheet 3 – Detail 3: Provide shear transfer detailing from roof diaphragm to braced wall below.