PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10483439
PROJECT ADDRESS:
2126 S Lyon St
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B, F-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/15/2014
These plans are approved, as soon as plans for plan check # 10483351 is resubmitted and approved, the permits can be issued for both of these plans.
INITIAL REVIEW
2/5/2015
EXPIRATION
6/13/2015
RECHECKS:
1.05-13-2015
PROJECT APPLICANT CONTACT PERSON:
2.
Michelle Bleeker
3.
TEL:
(949)701-5729
FAX:
(949)654-3957
VALUATION:$1,000.00
EMAIL:
tmtpermits@gmail.com
FLOOD ZONE:X-0602320278J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Orange County Fire Authority approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceOccupancies storing, handling, using, and/or selling hazardous materials, liquids, and chemicals shall submit a list of all said materials, listing their quantities and how they relate to specific California Building Code Table items. Note on the Floor Plan, type and quantity of hazardous material in each control area and fire-resistive rating for fire barriers.Since there are 2 plan checks under a “NOTICE of VIOLATION”, N/V, for this building; provide a note on the plan to read:” The permit for this plan check shall be issued at or after the permit for plan check # 10483351 is issued”. Provide structural calculation and construction details for the roof screen. The detail on sheet A-4.0 is not adequate. For the re check, please update the floor plan per new (proposed) floor plan submitted for plan check # 10483351.