HomeMy WebLinkAbout205475_1_Corrections.docxSPC
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10185003
PROJECT ADDRESS:
1059 W Third St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/7/2015
INITIAL REVIEW
6/11/2015
EXPIRATION
11/3/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Xavier Hernandez
3.
TEL:
(951)830-2018
FAX:
VALUATION:$27,500.00
EMAIL:
xavier@xavierdesigngroup.com
FLOOD ZONE:
APPLICABLE CODE: 2013 CALIFORNIA RESIDENTAIL CODE (CRC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A2: Provide braced wall at each corner of the new bathroom. Minimum length of braced wall shall be 4 foot minimum. Specify braced wall schedule on the floor plan. Braced wall schedule shall include material type, thickness, fastener type, minimum embedment, boundary nailing spacing, and field spacing.Sheet A2 Wall Section. Specify shear transfer detailing at rafter-ceiling to wall and bottom sill-plate to foundation where braced wall occurs.Sheet A2: Specify minimum three-foot dimension at landing where new exterior door is being proposed.Sheet A2: Specify tempered glazing at proposed window in the new bathroom unless the bottom edge of the glazing is 60 inches above the floor surface. Since elevation drawing was not provided, the height of the proposed window was not determined.
R308.4.5 Glazing and wet surfaces. Glazing in walls, enclosures or fences containing or facing hot tubs, spas, whirlpools, saunas, steam rooms, bathtubs, showers and indoor or outdoor swimming pools where the bottom exposed edge of the glazing is less than 60 inches measured vertically above any standing or walking surface shall be considered a hazardous location. This shall apply to single glazing and all panes in multiple glazing.
Exception: Glazing that is more than 60 inches, measured horizontally and in a straight line, from the water’s edge of a bathtub, hot tub, spa, whirlpool, or swimming pool.