Loading...
HomeMy WebLinkAbout205283_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10184932 PROJECT ADDRESS: 3202 S Shannon St PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/29/2015 INITIAL REVIEW 5/13/2015 EXPIRATION 10/26/2015 RECHECKS: 1. 06/11/2015 PROJECT APPLICANT CONTACT PERSON: 2. Don Beechan 3. TEL: (949)852-5900 FAX: (949)852-5909 VALUATION:$114,521.00 EMAIL: don@mvaarc.com FLOOD ZONE:X-0602320258J Recheck was completed today, 06/11/2015. Plans are approved subject to item # 5 in the original plan check list. APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceThe width of the level area on the side to which the door swings shall extend 24” past the strike edge of the door for exterior doors.Show compliance for the main entry door shown on sheet SP.Note on the drawings: “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding doors. Sanitary facilities serving the area of new work shall be disabled accessible. On the enlarged toilet room plan, please show all clearances and maneuvering spaces called out in CBC Sections: 11B-603 and 11B-604.Provide aroof plan and show the roof mounted equipment with proper construction details for their attachments.Show compliance with CBC Section 2406.4.2, glazing adjacent to door, for the following rooms on the plan; room # 103, 107, & 113.