Loading...
HomeMy WebLinkAbout207183_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10185594 PROJECT ADDRESS: 3700 W Warner Ave Unit# B PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): A-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/1/2015 INITIAL REVIEW 8/4/2015 EXPIRATION 12/28/2015 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Rosindo Tiritilli 3. TEL: (714)309-9021 FAX: VALUATION:$17,300.00 EMAIL: Rtiritilli@sbcglobal.net FLOOD ZONE:X-0602320258J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet S1: Provide ceiling plan to show point of connections at ceiling joists.Sheet S1: Calculations on roof-rafter and ceiling joists are unclear on the bending moment capacity. Sheet S1: Uni-struts are typically tie to the roof rafter for hood installations. Existing 2x4 ceiling joists members at 16” on center are inadequate without additional support.Sheet S1: Provide curb detail with flashing and use double rafter-joists at opening. Use blockings in between openings.