HomeMy WebLinkAbout205451_2_Corrections.docxRESIDENTIAL
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10184997
PROJECT ADDRESS:
1840 S Bamdal St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/6/2015
INITIAL REVIEW
7/1/2015
EXPIRATION
11/2/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Stephen Garcia
3.
TEL:
(562)665-8712
FAX:
VALUATION:$53,737.00
EMAIL:
FLOOD ZONE:X-0602320257J
APPLICABLE CODE: 2013 CALIFORNIA RESIDENTIAL CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet A1: Provide energy documentation on the plan.Sheet A2: Provide shear transfer detail at interior wall on the roof plan.Sheet A2: Roof plan shows roof trusses and conventional roof framing. Verify discrepancy. Provide roof truss shop drawings if truss design is chosen. In addition, revise roof truss details as necessary.Sheet A2: Identify braced wall on the plan. Specify braced wall length, type, location, and anchorage details on the plan.Sheet A2: Provide and cross reference dowel details between existing concrete slab and new concrete slab.Sheet A3: Specify minimum 50 cfm capability on exhaust fan in the bathroom.Sheet A3: Provide carbon monoxide device outside the proposed bedroom.Sheet A3: Specify minimum clearance dimension at water closet. See Code section below:
2010 CPC Section 407.5 Setting. Fixtures shall be set level and in proper alignment with reference to adjacent walls. No water closet or bidet shall be set closer than fifteen (15) inches from its center to any side wall or obstruction nor closer than thirty (30) inches center to center to any similar fixture. The clear space in front of any water closet or bidet shall be not less than twelve-four (24) inches. No urinal shall be set closer than twelve (12) inches from its center to any wall or partition nor closer than twenty-four (24) inches center to center.
Exception: The installation of paper dispensers or accessibility grab bars shall not be considered obstructions.