Loading...
HomeMy WebLinkAbout207919_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10185857 PROJECT ADDRESS: 2001 W Myrtle St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/27/2015 INITIAL REVIEW 8/13/2015 EXPIRATION 1/23/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Greg Weist 3. TEL: (626)705-3694 FAX: (626)705-7100 VALUATION: $49,115.00 EMAIL: FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet “T-1”Revise the occupancy group to “R-2” for residence and “U” for private garages.Add 2013 California Residential Code (CRC) under Current Codes.Show the setback distance from the face of exterior wall to center-line of the alley.Fire Separation Distances are less than 5 feet at the garage. Provide One-hour fire assembly detail for exterior wall.Sheet A-1Provide hold-down and anchor bolt details on foundation plan.Revise Section letter from “A” to “B” at the bottom left Section of the sheet.Section “B” indicates 5/8” type X drywall to roof sheathing. Show this information on detail “9/A2”.Detail 10/A-2 and keynote #7 indicate new footing. However, foundation shows existing footing to remain. Verify discrepancy.Floor plan and foundation plan are shown as existing structure. Details on plan suggest these plans are designed as “Proposed” construction.Detail “9/A2” is referenced on the foundation plan between new concrete footing and existing concrete footing. However, detail “9/A2” is a framing detail.Sheet A2Revise sheet number to “A2” at the bottom-right corner of the sheet.Rear elevation shows downspout locations. Provide a roof plan to show drainage pattern and slope.Specify boundary nailing for shear transfer on detail 6 and detail 7.Specify anchor bolt minimum embedment on detail 8.