HomeMy WebLinkAbout208105_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10185918
PROJECT ADDRESS:
2912 W Elder Ave
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/3/2015
INITIAL REVIEW
9/1/2015
EXPIRATION
1/30/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Daisy Whitehead
3.
TEL:
(714)549-0395
FAX:
VALUATION: $50,000.00
EMAIL:
FLOOD ZONE: X-0602320256J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.Sheet “T-1”: Energy sheets are missing on the plan.Sheet “A1.1”: The proposed exterior wall is less than 5 feet from the property line. Provide a one-hour fire rated construction detail for the exterior wall eave-underside protected detail.Sheet “A2.1”: Architect’s signature is required on all sheets.Sheet “A2.1”: Specify exhaust fan with minimum 50 cfm in the bathroom.Sheet “A2.1”: Specify tempered glazing near the new door at the living room.Sheet “A2.1”: Provide structural calculations for the new 4x14 beam.Sheet “A2.2”: Revise sheet-number reference on foundation plan.Sheet “A2.2”: Show braced-wall type, length, and location on plan.Sheet “A2.2 – Detail B”: Specify pressure treated sill plate.Sheet “A2.2 – Detail B”: Insulation R-15 is less than prescriptive standard. Provide energy documentation to show Energy envelop compliance.Sheet “A2.2 – Detail B”: Specify the type of posted-installed anchor bolt on existing concrete.Sheet “A2.2 – Detail B”: Specify 3 inches square plate washer.Sheet “A2.2 – Detail F”: Simpson hardware “A34” is no longer available on the market. Sheet “A3.1”: Show two roof-dormers on elevation drawings.