Loading...
HomeMy WebLinkAbout209648_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10186405 PROJECT ADDRESS: 1625 E St Gertrude Pl PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/2/2015 INITIAL REVIEW 9/18/2015 EXPIRATION 2/29/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Marcus Kemmerer 3. TEL: (714)655-3139 FAX: (714)969-9059 VALUATION:$32,500.00 EMAIL: Marcus@kaarch.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet T-1: Sheet Index indicates Sheet A3. However, sheet A3.1 is missing on plan.Sheet T-1: Specify the Type of Construction to either V-A or V-B under Drawing Directory.Sheet T-1: Include Structural sheets under Sheet Index.Sheet T-1: Remove reference “UMC” and “UPC” under Drawing Directory.Sheet A1.0: Show access aisle width on the site plan.Sheet A1.0: Cross reference detail 9/A1.1 on the accessible parking stall. Sheet A1.0: Specify the total number of parking spaces provided on site. Specify total number of accessible parking provided. Minimum of one accessible parking space shall be a “VAN” space. Identify “Van” space location on the site plan.Sheet A1.2: Provide referenced-detail number for the full height wall under Wall Legend.Sheet A1.2: Specify tempered glazing on all windows within 2 feet of doorways.Sheet A1.2:At least one window/ counter shall be accessible. Provide counter detail and Knee & Toe clearance detail at the waiting area.Sheet A1.2: Provide door schedule.Sheet A1.2: Provide minimum 18 inches strike-edge dimension at hallway and between the break room.Sheet A1.2: Provide an enlarged detail for bath room and show all required dimensions on accessible features in the bathroom.Sheet S-1: Provide Engineer’s signature on sheet S1 and provide structural calculations for plan check.