HomeMy WebLinkAbout209854_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10186482
PROJECT ADDRESS:
2431 S Anne St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/10/2015
INITIAL REVIEW
10/7/2015
EXPIRATION
3/8/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
George W Seitz
3.
TEL:
(949)250-1018
FAX:
VALUATION:$18,058.00
EMAIL:
FLOOD ZONE:X-0602320258J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet A-1Specify hardware height and hardware type at the proposed gate.Specify gate width on detail 3.Provide rolling-gate shop drawing for plan review.Provide footing detail for rolling gate. In addition, specify footing location on plan.Revise detail-referenced sheet number on parking detail.Verify the color of painted striping on standard parking stalls.Delete “Van Accessible” lettering on the access aisle.Keynote 14 indicates exit door per door schedule. However, door schedule is not found on plan.Verify referenced number on keynote 11 and 16.Specify door landing width on the site plan.Provide “Scope of Work” under Project Information.Specify the type of construction to either “V-A” or V-B” under Project Information.Sheet A-2Specify hardware type and height per egress requirements on keynote 4.Report number 5173 is not found on ICC website. Verify report number on detail 3.Verify referenced number on detail 3. Specify ceiling height on detail 4.Sheet A-3Revise code edition to “2013” on note under Truncated dome Section.Update code section reference number under Truncated dome Section.