HomeMy WebLinkAbout208075_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10185906
PROJECT ADDRESS:
1417 W Warner Ave
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/30/2015
INITIAL REVIEW
8/13/2015
EXPIRATION
1/26/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Arean Park
3.
TEL:
(714)990-1200
FAX:
VALUATION:$30,000.00
EMAIL:
FLOOD ZONE:X-0602320259J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet A1Specify total number of parking spaces provided on site.Specify total number of accessible parking spaces provided on site.Specify number of van accessible parking space provided on site.
11B-208.2.45 Van parking spaces. For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502.Sheet A2Detail 6 indicates the parking space is a van accessible parking space. Van accessible parking space shall have access aisle located on the passenger side of the parking space.
11B-502.3.4 Location.Access aisles shall not overlap the vehicular way. Access aisles shall be permitted to be placed on either side of the parking space except for van parking spaces which shall have access aisles located on the passenger side of the parking spaces.At least one van accessible parking space is required on the site plan. The access aisle width shall be 8 feet minimum.
11B-502.2 Vehicle spaces. Car and van parking spaces shall be 216 inches long minimum. Car parking spaces shall be 108 inches wide minimum and van parking spaces shall be 144 inches wide minimum, shall be marked to define the width, and shall have an adjacent access aisle complying with Section 11B-502.3.
Exception: Van parking spaces shall be permitted to be 108 inches wide minimum where the access aisle is 96 inches wide minimum.Provide the following specifications on Marking.
11B-502.3.3 Marking. Access aisles shall be marked with a blue painted borderline around their perimeter. The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches on center in a color contrasting with that of the aisle surface, preferably blue or white. The words “NO PARKING” shall be painted on the surface with each access aisle in white letters a minimum of 12 inches in height and located to be visible from the adjacent vehicular way. Access aisle markings may extend beyond the minimum required length.Specify 4’-0” minimum by 4’-0” minimum at the bottom of the curb ramp.
11B-406.3.2 Turning Space.A turning space 48 inches minimum by 48 inches minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be 1:48 maximum.Detail 5: The maximum adjoining slope shall not exceed 1:12. Revise note as necessary.
11B-406.3.2 Turning Space.A turning space 48 inches minimum by 48 inches minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be 1:48 maximum.Detectable warning surfaces color shall be yellow on a curb ramp. Revise note #1.
11B-705.1.1.3.1 Detectable warning surfaces shall be yellow and approximate FS 33538 of Feferal Standard 595C.Sheet A3Detail 5: The minimum dimension between exposed earth and bottom of sill plate shall be 8 inches. Revise dimension on detail.