Loading...
HomeMy WebLinkAbout207102_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10185566 PROJECT ADDRESS: 1109 S Flower St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/2/2015 INITIAL REVIEW 8/5/2015 EXPIRATION 12/29/2015 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ruben Pena 3. TEL: (714)552-5731 FAX: VALUATION: $72,455.00 EMAIL: rpena@inkminded.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Energy analysis and documentations were not provided. The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.Sheet 1Specify occupancy group “R3/U” under Building Data.Specify type of construction “V-B” under Building Data.Specify floor-area for proposed patio under Building Data.Complete information under Legal Description.Sheet 8 is missing on the plan.Revise all code editions to “2013”. In addition, add “2013 California Residential Code” as part of a governing code on constructions and designs.Sheet 2The Fire Separation Distance between the exterior wall at the garage and property line is less than 5 feet. One-hour fire assembly at exterior wall and One-hour fire protection under the eave are required. Provide details to show compliance.Show landing dimensions near the master bedroom.Provide one carbon monoxide device outside the bedrooms.Provide ICC report number for skylight. The ICBO number provided is outdated.Show North arrow on the site plan.Specify 50 cfm minimum for the exhaust fan.Provide attic ventilation calculations on plan.Show steps at landing on the floor plan. In addition, specify minimum tread dimension.Sheet 3Show ceiling joist overlap detail at interior wall.On foundation plan, hold-down model “HPAHD22” is specified. However, model “HPAHD22” is not found in Simpson catalog.Specify interior shear transfer detail at shear wall between new bedroom and existing bedroom.Sheet 4Detail 2: the minimum distance between sill plate and exposed earth shall be 8 inches.Sheet 7The shear-wall schedule’s structural capacity is outdated. Revise table per current Code as necessary.