HomeMy WebLinkAbout211559_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10187138 PROJECT ADDRESS: 2001 E Catalina Ave PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/9/2015 INITIAL REVIEW 11/23/2015 EXPIRATION 5/7/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Lori A. Gennusa 3. TEL: (714)335-8199 FAX: VALUATION:$11,718.00 EMAIL: gennusa@sbcglobal.net FLOOD ZONE:X-0602320164JPlease indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.] The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Show location of minimum 20x30-inch attic access with 30-inch minimum headroom. provide at least one openable emergency escape and rescue window for second existing bedroom shown on sheet A1 to meeting all of the following: -An openable area of not less than 5.7 square feet (5.0 square feet for ground-floor openings); -A minimum 24 inch clear openable height; -A minimum clear openable width of 20 inches; -A sill height not over 44 inches above the floor. The City has encountered a large number of inspection problems arising from a lack of specific framing details. The following listed items are required to be shown on the plans: -All plumbing walls are to be framed with a minimum of 6" studs. -Double walls used as plumbing walls are to be a minimum of 8" wide and no "flat" studspermitted. Staggered studs are acceptable. -Notching of exterior and bearing/nonbearing walls shall not exceed 25%/40% respectively. Bored holes in bearing/nonbearing walls shall not exceed 40%/60% respectively. In no case shall the edge of the bored hole be nearer than 5/8 inch to the edge of the stud. For detail 3/S1, provide a strap at the ceiling joists connecting to the new proposed Beam to maintain the continuity of the existing structure. See red mark on this detail. Is there any header above the washer/dryer space?