HomeMy WebLinkAbout209485_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10186356
PROJECT ADDRESS:
1126 S Shelley St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/26/2015
INITIAL REVIEW
9/14/2015
EXPIRATION
2/22/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Jesus Blanquel
3.
TEL:
(562)244-4814
FAX:
VALUATION: $54,173.00
EMAIL:
jesseblanquel161@yahoo.com
FLOOD ZONE: X-0602320257J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A-1Revise the Occupancy group to “R-3/ U” under Project Summary.Add 2013 California Residential Code (CRC) under Project Summary.Include all structural sheets and energy sheets under Table of Contents.Specify eave-overhang dimension on the site plan.Sheet A-2Enlarge texts in Door Schedule and Window Schedule.Some windows and doors are shown as “New” and “Existing” under Door Schedule and Window Schedule.Show electrical receptacle locations on the floor plan.Provide legend and specify exhaust fan to have minimum 50 cfm capability.Show exterior landing and dimensions near the living area.Use a different legend for “Pony Wall”.Verify if the existing window remains unfilled between the existing bedroom and proposed bedroom.Verify the North Arrow direction. It does not match elevation drawings on sheet A4.Sheet A-3Specify roof slope on plan.Roof plan indicates 487 sq foot addition. However, title sheet shows 497 sq foot addition. Verify discrepancy.Show roof ventilation devices on roof plan and elevation drawings. Provide calculations on minimum roof ventilation area.Sheet A-4East elevation is missing a window and a door. See floor plan for location.Exterior elevation note 2 indicates electrical plan for lighting reference. However, electrical plan is not found on plan.Exterior elevation note 9 indicates raised-floor foundation. However, structural foundation plan shows concrete slab on grade details.Sheet S-1Specify ridge-board size per detail “1/SD1”.