Loading...
HomeMy WebLinkAbout211864_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10187248 PROJECT ADDRESS: 3960 S Main St Unit# D PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/19/2015 INITIAL REVIEW 1/22/2016 EXPIRATION 5/17/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Cassandra Duerscheidt 3. TEL: (949)302-9518 FAX: VALUATION:$80,000.00 EMAIL: FLOOD ZONE:X-0602320278J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet 1Restroom layout per detail 8 on sheet 1.1 does not match the floor plan. Revise detail as necessary.Show 18 inches strike-edge distance at men and women’s doorways.Sheet 1.1Revise dimension between face-of-wall and center-line of water closet on detail 7.11B-604.2 Location. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 17 inches minimum to 18 inches maximum from the side wall or partition, except that the water closet shall be 17 inches minimum and 19 inches maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in Section 11B-604.8.2. Water closets shall be arranged for a left hand or right-hand approach.Relocate lavatory location per floor plan.Provide additional minimum dimension and maximum dimension at signage as follow: 11B-703.4.1 Height above finish floor or ground. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface measured from the baseline of the lowest Braille cells and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters.