HomeMy WebLinkAbout211520_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10187122
PROJECT ADDRESS:
1395 S Lyon St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B, F-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/5/2015
INITIAL REVIEW
11/18/2015
EXPIRATION
5/3/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Vincent Baroldi
3.
TEL:
(714)447-0893
FAX:
(714)447-1443
VALUATION: $60,000.00
EMAIL:
Vince@bridge-cranes.com
FLOOD ZONE: X-0602320276J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A01Provide “Scope of Work” on title sheet.Provide the following Building Data:Occupancy Group: (See Section 302)Type of Construction: (Section 602)Number of stories:Sprinkler: Yes or No?Floor area of building:Revise general note #3 to “2013 California Building Code”.Please update reference per 2013 California Building Code on Steel and Welding note #1 and #2.Please specify either continuous inspection or periodic inspection per 2013 CBC Table1705.2.2 & Table 1705.3.Sheet A02Revise the referenced-detailed number on the plan view.Provide a floor plan and show location of new cranes.Show crane 1 (W24x104) location on plan. (Calculation page #5)Show crane 2 (W24x117) location on plan. (Calculation page #10)Design of HSS12.75x0.375 per calculation page 21 is not shown on plan.Foundation footing 5’x5’x4’ deep per calculation page 27 is not shown.Sheet A03Detail 3 shows ¾”x8”x20” cap steel plate. Please provide structural design calculations for the steel plate design.