HomeMy WebLinkAbout212372_1_Corrections.docx PLAN CHECK NO: 10187436 PROJECT ADDRESS: 1229 S. Harmon St. PLAN CHECK ENGINEER: Anson SoTEL:714 -647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V-B OCCUPANCY CLASSIFICATION(S): PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION INITIAL REVIEW 01/22/15 EXPIRATION RECHECKS: 1 PROJECT APPLICANT CONTACT PERSON: 2. John Nguyen 3. TEL: 714-904-9518 FAX: VALUATION: $76,191 EMAIL: nguyenjdl@yahoo.com FLOOD ZONE: X Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3 corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A-1Relocate detail reference “20/SD-1” to Left-Hand-Side of the proposed exterior wall.Sheet A-2Show exterior landing and dimensions near Bedroom (4) and new family room.R311.3 Floors and landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼ unit vertical in 12 units horizontal (2 percent)Exception: Exterior balconies less than 60 square feet and only accessible from a door are permitted to have a landing less than 36 inches measured in the direction of travel.Specify tempered glazing in new bathroom (3) if the bottom edge of glazing is less than 60 inches above finished floor. From the elevation drawing on sheet A-4, the bottom edge of glazing measured below 60 inches above finished floor.R308.4.5 Glazing and wet surfaces. Glazing in walls, enclosures or fences containing or facing hot tubs, spas, whirlpools, saunas, steam rooms, bathtubs, showers and indoor or outdoor swimming pools where the bottom exposed edge of the glazing is less than 60 inches measured vertically above any standing or walking surface shall be considered a hazardous location. This shall apply to single glazing and all panes in multiple glazing.Exception: Glazing that is more than 60 inches, measured horizontally and in a straight line, from the water’s edge of a bathtub, hot tub, spa, whirlpool, or swimming pool.Sheet A-3 & SD-1Provide Engineer On Record’s stamp and signature on all structural drawings.