Loading...
HomeMy WebLinkAbout212094_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10187336 PROJECT ADDRESS: 1508 Brookhollow Dr PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/25/2015 INITIAL REVIEW 12/9/2015 EXPIRATION 5/23/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Kelly Bird 3. TEL: (714)505-5341 FAX: VALUATION:$501,092.00 EMAIL: Kbird@rengelarch.com FLOOD ZONE:X-0602320278J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceRevise the drawings to show compliance with CBC Section 1008.1.2 for doors to conference rooms # 108 & 216 plus training room # 221.It is the project designer’s/property owner’s responsibility to show compliance on the drawings with all applicable Federal and State Accessibility Standards.Show compliance with CBC Sections 11B-202.3, 11B-206.2.3 item # 1.2 and 11B-206.2.4 for the following rooms on the second floor: training room, break room, coffee bar, conference room and the lunch area.Please provide the ICC report number for the proposed skylights and they are shown on S-2 sheet.See red marks on the following sheets of plan. Sheets: A111, A210, A211, A300, A601, S-1, & S-2. Please resubmit the marked up set with revised plans for recheck.