HomeMy WebLinkAbout212523_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10187482
PROJECT ADDRESS:
1501 N Harbor Blvd
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/10/2015
INITIAL REVIEW
12/22/2015
EXPIRATION
6/7/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
James Kim
3.
TEL:
(213)923-1317
FAX:
VALUATION:$50,000.00
EMAIL:
jamesinkim@gmail.com
FLOOD ZONE:A-0602320143JAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.
All revised drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered engineer. All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a).
This review does not include electrical work. Separate plan, application, fee, plan check, and permitis required for electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.For roof covering specify for the roof extension:
-Manufacturer and type of built-up roof.
-Roof slope(s) of all new areas on the roof plan.
-Roof coverings shall have at least a Class "C" rating. Show the location(s) of Carbon monoxide alarm(s) in each unit per Section 420.6.2.2 of CBC.Provide construction details and structural calculation for the new guards at the extended edge of balcony. Guard shall have a minimum of: 42 inch high with openings between balusters/rails shall preclude passage of 4 inch. See Section 1013 of CBC.The guards assemblies shall be designed to resist a load of 50 plf applied in any direction at the top and to transfer this load through the supports to the structure. Also, it has to resist a concentrated load of 200 pounds applied in any direction at any point along the top, and have attachment devices and supporting structure to transfer this load to appropriate structural elements of the building. The following items on the cover sheet shall be updated; occupancy group for this motel is R-1 and the code reference for the note # 19 shall change from r315.1 to CBC 420.6.2.2.