HomeMy WebLinkAbout213534_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10187798 PROJECT ADDRESS: 1226 S Rosewood Ave PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/29/2015 INITIAL REVIEW 1/7/2016 EXPIRATION 6/26/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Leticia Portocarrero 3. TEL: (714)721-3412 FAX: VALUATION:$50,644.00 EMAIL: lettyp67@yahoo.com FLOOD ZONE:X-0602320257JResubmit 3corrected sets of plans.Show the location(s) of carbon monoxide alarm and smoke alarms on the floor plan. Show location of 20 x 30 inch attic access with 30-inch minimum headroom for the proposed addition. Due to omitting the exterior window for the existing bathroom, Provide exhaust fan with humidity control complying with CRC Section R303.3.1 for this existing bathroom. The residence shall conform to the State Energy Conservation Standards. Submit forms and calculations for review and blueprint the final forms on the plans. -The permit applicant shall be responsible for obtaining an energy plan check from a consultant who is qualified to perform an energy efficiency analysis in accordance with the California Code of Regulations (CCR), Title 24, Part 1 (Administration) and Part 6 (2013 California Energy Code). The plan check consultant must sign documentation certifying that a thorough, competent review has been performed on behalf of the Enforcement Agency. -The energy plan check consultant must sign documentation forms on behalf of the Building Safety Division. Note on the plans that foundation anchor bolts in walls shall have an approved plate washer under each nut; and the nuts shall be tightened just prior to covering the wall framing. Plate washers a minimum of 3 inch by 3 inch by 0.229 inch thick shall be used on each bolt.