HomeMy WebLinkAbout214840_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10188198/99
PROJECT ADDRESS:
816 N Figueroa St Bldg# C
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK Story Increase
OCCUPANCY CLASSIFICATION(S):
U, R-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
2/9/2016
INITIAL REVIEW
3/1/2016
EXPIRATION
8/7/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Ramon Acuna
3.
TEL:
(714)604-5818
FAX:
VALUATION:
EMAIL:
racuna@c-cdev.com
FLOOD ZONE:X-0602320143JResubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The truss shop drawings/information submitted for Building Safety Division review is incomplete. The roof framing plan shown on sheet S-1.4 has a ridge line with hips going down at the two ends of roof. The truss shop drawing shows flat area on top portion of the roof. Please verify this condition with the designer and resubmit the corrected truss drawings for review and approval.