HomeMy WebLinkAbout213528_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10187796
PROJECT ADDRESS:
4422 W Regent Dr
PLAN CHECK ENGINEER:
Chehade, NabilTEL:714
647-5848FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/29/2015
INITIAL REVIEW
2/16/2016
EXPIRATION
6/26/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Byron Do
3.
TEL:
(714)856-5704
FAX:
VALUATION:$48,097.00
EMAIL:
bydezygn@yahoo.com
FLOOD ZONE:X-0602320256J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2007 California Building Code (CBC); MC = 2007 California Mechanical Code; PC = 2007 California Plumbing Code; EC = 2007 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
- Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
-State Division of Occupational Safety Permit (Cal/OSHA) (939-0145).
Construction of trenches or excavations, which are five feet or deeper and into which a person is
required to descend.
The construction or demolition of any building, structure, false-work, or scaffolding more than
three stories high or the equivalent height.Include address and telephone number of the responsible designer and date of signing of drawings.
In addition to other fees, a "Park Acquisition and Development Fee" in the amount shownbelow
shall be required pursuant to a resolution of the City Council for the Recreation andCommunity
Services Agency; net addition of 2 bedroom(s).Amount of $5,998.43; net addition of 5 bedroomsAmount of $5,391.50; net addition of 4 bedroomsAmount of $4,869.15; net addition of 3 bedroomsAmount of $3,629.16; net addition of 2 bedroomsAmount of $2,723.74; net addition of 1 bedroomShow 30-inch clear width for water closet compartments and 24-inch clearance in front of a water closet. Show location of heating equipment on the plans. (CRC R303.8)Carbon monoxide alarms combined with smoke alarms shall comply with both sections R314 and section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms.When more than one smoke alarm or carbon monoxide alarm is required to be installed within an individual dwellingunit the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit.Please note the ceiling is acting as a rafter tie, preventing the walls from moving out of plumb; provide a proper nailing detail for the attachment of the ceiling joist to the rafter. The detail provided is showing two of the nails outside the effective location to fasten the ceiling joist to the rafter.