HomeMy WebLinkAbout215278_1_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10188353 PROJECT ADDRESS: 816 N Figueroa St Bldg# A PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: UnKnown OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/24/2016 INITIAL REVIEW 3/31/2016 EXPIRATION 8/22/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Aleks Ambalada 3. TEL: (858)336-4602 FAX: VALUATION:$15,000.00 EMAIL: aleks@californiasolarthermal.com FLOOD ZONE:X-0602320143J APPLICABLE CODE: 2007 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer. CBC Sections A106.1 and A106.3.4.1.All drawings shall be signed by the person who prepared these plans and specifications.Include address and telephone number of the responsible designer, and date of signing of drawings.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance. Show a floor plan with the location of the storage tank.Provide support for the storage tankSpecify the occupancy group and the type of construction of the buildings.Show locations of all fire walls, fire partitions and fire barriers and clarify how you intend to make the pipe penetrations and any walls that you intend to open up to install any pipes and reseal it.Please note this project is for an apartment building where the floor and the roof might be fire rated. In addition all the partitions separating the units are fires rated and have an STC rating. Please provide details to show which walls are being penetrated, the fire rating of the wall, and a detail that shows compliance with the code. In addition, some of the wall might have to be opened up; and hence a detail showing how to close the wall and maintain the rating of the wall need to be provided on plans.Provide a floor plan that shows where these pipes will be located.If these pipes are going into exterior walls, the fire rating of the wall and the fire separation distance from the property line or from any assumed property line should be shown on plans. If there are more than one building on the site, the distances between the buildings should be shown on the plans.Note to plan checker: these are multiple permits 10188353, 10188354, 10188355, 10188356, complete screens for all of them.