HomeMy WebLinkAbout213635_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10187834 PROJECT ADDRESS: 2218 S Rosewood Ave PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/31/2015 INITIAL REVIEW 2/23/2016 EXPIRATION 6/28/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Arthur Dickerson 3. TEL: (714)775-7244 FAX: VALUATION:$54,530.00 EMAIL: artdickersonclassactbuilders@yahoo.com FLOOD ZONE:X-0602320259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2007 California Building Code (CBC); MC = 2007 California Mechanical Code; PC = 2007 California Plumbing Code; EC = 2007 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Recheck should be done by an appointment with the plan reviewer. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.] The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.Walls of dwelling units and accessory buildings without an automatic residential fire sprinkler protection with a fire separation distance less than 5 feet are required to have a full one hour rating. (CRC Table R302.1 (1)) Please specify 5/8 type X to qualify for the 1-hour const.Show location and size of all fire escape from all bedrooms existing and new.( show the size of the opening and height above floor for the small window of the existing bedroom next to the study.Provide a connection detail of the ceiling joists; please note that the ceiling joists are acting as rafter tie. Connection has to be strong enough to withstand tension force.(connection in question is for the ceiling ties when not a continuous member).Based on the calculations the area of the proposed bedroom is 480 sqft. I am not quite sure why it is crossed out.(Per the scale provided the dimensions are wrong. All plans must be drawn to scale).Provide a strap between the new PSL at the patio area and the shear wall.(10/4 as indicated in your correction reference is a wrong detail for the strap of the PSL).