HomeMy WebLinkAbout211864_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10187248
PROJECT ADDRESS:
3960 S Main St Unit# D
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/19/2015
INITIAL REVIEW
1/22/2016
EXPIRATION
5/17/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Cassandra Duerscheidt
3.
TEL:
(949)302-9518
FAX:
VALUATION:$80,000.00
EMAIL:
FLOOD ZONE:X-0602320278J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet 1Restroom layout per detail 8 on sheet 1.1 does not match the floor plan. Revise detail as necessary.Show 18 inches strike-edge distance at men and women’s doorways.Sheet 1.1Revise dimension between face-of-wall and center-line of water closet on detail 7.11B-604.2 Location. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 17 inches minimum to 18 inches maximum from the side wall or partition, except that the water closet shall be 17 inches minimum and 19 inches maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in Section 11B-604.8.2. Water closets shall be arranged for a left hand or right-hand approach.Relocate lavatory location per floor plan.Provide additional minimum dimension and maximum dimension at signage as follow: 11B-703.4.1 Height above finish floor or ground. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface measured from the baseline of the lowest Braille cells and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters.