HomeMy WebLinkAbout216256_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10188710/711/712/713/ & 714 PROJECT ADDRESS: 2800 N Main St Unit# 556 PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: II B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/24/2016 INITIAL REVIEW 4/12/2016 EXPIRATION 9/20/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Saied Shantiyaie 3. TEL: (909)860-1010 FAX: VALUATION:$20,000.00 EMAIL: sshantiyai@ladesigngroup.net FLOOD ZONE:X-0602320163J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceFloor live load. The uniformly distributed floor live load for storage area is 125 PSF. The existing retail space was not designed for more than 75 PSF. Provide structural analysis for these storage areas to justify that the existing floor can resist storage live load or provide the reinforcement for existing floor framing to increase its capacity for proposed use.Provide a rated door between rated corridor in the back & the tenant space # 556 to comply with chapter 10 of CBC.