HomeMy WebLinkAbout214032_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10187948
PROJECT ADDRESS:
829 N Bristol St
PLAN CHECK ENGINEER:
Chehade, NabilTEL:714
647-5848FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/14/2016
INITIAL REVIEW
3/4/2016
EXPIRATION
7/12/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Cynthia Zavala
3.
TEL:
(323)229-4110
FAX:
VALUATION:$15,000.00
EMAIL:
cynthia@ultimatedrafting1.com
FLOOD ZONE:X-0602320144J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2007 California Building Code (CBC); MC = 2007 California Mechanical Code; PC = 2007 California Plumbing Code; EC = 2007 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.]
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
Please indicate that the smoke alarm and Carbom monoxide alard to be hard wired.
Report of fire damage indicates that some of the floor joists are to be replaced, indicate which and what size.
Is the porch going to be enclosed? Can’t tell from the plans.
Any of the existing plywood acting as shear walls wis going to be replaced?
Specify where the plywood shown on the plan will be installed.
Detain 4 on S1.2 is inconsistent with the plans. Provide an appropriate detail.
Detail 5 on S1.2 is called out but not provided.
Is the 4x8 supporting the king post or viseversa. Clarify.
The ridge is shown to be supported on a king post that is going nowhere. If the 4x8 is supported on the existing 4X post, please show how.
Detail 7 on S1.2, is this a concrete footing or concrete slab?
Are any of the kitchen walls and/or porch railing, stairs are to be replaced? If so make sure is identified on the plans.