HomeMy WebLinkAbout208572_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10286085 PROJECT ADDRESS: 1612 E Palm St Unit# A PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3.1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/18/2015 INITIAL REVIEW 11/5/2015 EXPIRATION 2/14/2016 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. SaeedKamkar 3. TEL: (949)307-2723 FAX: VALUATION: $130,000.00 EMAIL: Saeed@saeeddesignstudio.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A-1Please provide a detailed “Scope of Work” on the title sheet. There are construction work performed without permit, proposed remodel of existing permitted space, proposed garage for employee, existing garage being converted to storage/laundry room, and a change of use from Residential occupancy group “R-3” to “R3.1”.Revise the occupancy group to “R3.1”under Legal Description.Will there be “Bedridden” clients in this facility? See 2013 CBC Section 903.2.8 for fire sprinkler requirements and exceptions. Specify on plan if this building is equipped with fire sprinkler or not.Identify garage as “existing construction” or “proposed construction” on the site plan.Two parcel lines are located across the buildings. A lot-line adjustment or a lot-tie shall be recorded legally prior to building permit issuance.Verify if separately address is required for separate units proposed.On the site plan, specify skylight as new construction since it was built without a permit.Site plan indicates new ramp is proposed near the sidewalk. Contact Public Works Department for encroachment permit if required.Sheet A-2Provide information for proposed skylights: Product name, model, size, and ICC report number.Sheet A-3Provide guide details and structural connection details at proposed ramp.Specify slope on ramp.Provide details for the proposed one-hour fire rated wall.The covered porch is connected with two units. Therefore, the fire rated wall shall be continuous from the front door to the exterior wall of bedroom #6.Floor plan shows bedroom number 1, 2 and 3 on the left unit and bedroom number 1, 3, and 6 on the right unit. Revise bedroom numbers as necessary.Specify fire rating at doors.Sheet A7Provide smoke detector outside the bedrooms.