HomeMy WebLinkAbout217304_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10189045
PROJECT ADDRESS:
321 E Normandy Pl
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/25/2016
INITIAL REVIEW
5/23/2016
EXPIRATION
10/22/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Hector Sanchez
3.
TEL:
(323)229-241
FAX:
VALUATION: $11,378.00
EMAIL:
FLOOD ZONE: X-0602320276J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a).
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following prior to building permit issuance:Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.Note on the Drawings:
Number of stories:
Existing building area:
New building area:
Area of existing garage:
Area of new garage:
Provide existing and proposed contours/spot elevations to indicate general site slope and drainage pattern. (A105.3 and 106)
Sheet A1.0Revise code edition to “2013 California Energy Code” under Building Code.Revise code edition to “2013 California Residential Code” under Building Code.Specify proposed “Storage” under Scope of Work. In addition, specify on plan proposed storage room shall not be used as a “Bedroom”.
Sheet A2.0Revise sheet number to “A2.0” at bottom right-corner of the sheet.Provide ICC report number for proposed skylight.Revise the cross-sectional number to “A/S-1”.Show roof drainage at parapets on North Elevation drawing.
Sheet S-1Garage plan indicates braces wall details. However, garage construction is not within the scope of this permit. Remove details as required.Specify header size on left side of the patio.Specify rafter to header beam detail on left side of the patio.Provide shear transfer detail at braced wall.Wood Framing note number one references Table 23-1. Provide Table 23-1 on plan.Revise detail number to “6/D1” at footing on foundation plan.Hold-down detail on sheet D-1 shows hold-down model HD2 & HD4. However, plan indicates hold-down model “HDU”. Verify discrepancy.Cross section BB shows ridge beam size 4’x8’. However, detail A/D-1 shows 2x8 ridge board. Verify discrepancy.
Sheet D-1Detail 4 shows 4x6 posts. However, plan shows 4x4 posts. Verify detail.