HomeMy WebLinkAbout218473_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10189375
PROJECT ADDRESS:
3226 W Hood Ave
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/31/2016
INITIAL REVIEW
7/7/2016
EXPIRATION
11/27/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Hung Le
3.
TEL:
(562)412-1818
FAX:
(562)868-4946
VALUATION: $5,000.00
EMAIL:
Le.Hung4946@yahoo.com
FLOOD ZONE: X-0602320256J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.The proposed patio-enclosure design covers the area adjacent to egress window on Bedroom #4. Egress window shall be open to the area that is open to the sky. Revise design as necessary.Provide structural connection detail between wall enclosure and existing roof structure.Provide structural connection detail between wall enclosure and footing.Provide footing detail.Specify patio enclosure height.Detailing indicates metal framed wall per manufacturing. However, manufacturing details were not provided.Provide structural details on the solid-wall with vinyl siding on West exterior wall.Specify no drywall on ceiling and interior walls.Specify existing foundation element. Carpet is not permitted within patio-enclosure area.Revise Governing Code edition to “2013 California Residential Code” on the title sheet.