HomeMy WebLinkAbout218518_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10189386/ 387
PROJECT ADDRESS:
2122 S Shelton St
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
6/1/2016
INITIAL REVIEW
6/2/2016
EXPIRATION
11/28/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Leticia Portocarrero
3.
TEL:
(714)721-3412
FAX:
VALUATION:$75,699.76
EMAIL:
lettyp67@yahoo.com
FLOOD ZONE:X-0602320257JAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
- School District Compliance Certificate; and a copy of the building permit application, signed by
the plan check engineer, shall be required by the School District to verify the scope of the work.
Due to removal of the existing window from the existing bathroom, provide an exhaust fan with humidity control for this bath room.Show the location(s) of all hard-wired smoke alarm(s) with a battery back up in each sleeping room and at a point centrally located in the corridor or area giving access to each sleeping area.See red marks on sheet 2 of drawings.South elevation show on sheet 3 is missing windows. See red marks on this sheet of drawing.From the new CRAWL SPACE provide an access path to existing and new raised floor areas. See red marks on sheet 4 of drawing for potential access paths.In order to convert the existing garage to a car port, provide full structural supports and construction details for this conversion. See red marks on sheets 4 & 5 of drawings for this item.Provide missing construction details as marked on sheet 5 of drawings.See other red marks on proposed framing plan on sheet 7.The permit applicant shall have the attached form completed and signed by an energy consultant other the energy consultant who prepared the Title 24 energy calculation.