HomeMy WebLinkAbout217125_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10188986
PROJECT ADDRESS:
313 S Maxine St
PLAN CHECK ENGINEER:
Chehade, NabilTEL:714
647-5848FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/19/2016
INITIAL REVIEW
5/11/2016
EXPIRATION
10/16/2016
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Sony La
3.
TEL:
(714)548-2394
FAX:
VALUATION: $53,955.00
EMAIL:
sonla714@yahoo.com
FLOOD ZONE: A-0602320252J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing CodeI; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.
Items not signed off are clarified in bold letterMeetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.
All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1).All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a).
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
-Grading Permit. Application is made through the Building Safety Division (647-5800) and the
plan review is by the Public Works Agency (647-5039).Provide lateral analysis for the whole house since the majority if the roof is new.(The area of concern is the lateral for the area above the kitchen/living room. The whole roof is new and there is a proposed large opening at the fron the takes ou most of the wall..Line C in Calcs The lateral force is devided by 8, use 3ft since this is a perforated wall and check for overturning.(Line C is a concern because it is impacted on both side; where are the shear wall along this line?)Detail 14 on D2, show the knee brace in both direction , parallel to the front of the house and perpendicular to the front of the house.( point the arrow shown on S2 to both sides otherwise it is not clear).