HomeMy WebLinkAbout221374_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10190282 PROJECT ADDRESS: 3760 W McFadden Ave Unit# C Bldg# L PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/4/2016 INITIAL REVIEW 8/20/2016 EXPIRATION 1/31/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Tom Han 3. TEL: (714)493-7088 FAX: VALUATION:$90,000.00 EMAIL: TH@thnenterprises.com FLOOD ZONE:X-0602320256J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.SHEET T-1Show Path of Travel to Entrance of the building.Include suspended ceiling installation under Scope of Work.Revise the Type of Construction to “V-B”.Revise the dimensional detail on the grab-bar. See section below:11B-609.4 Position of grab bars. Grab bars shall be installed on a horizontal position, 33 inches minimum and 36 inches maximum above the finish floor measured to thetop of the gripping surface, except that at water closets for children’s use complying with Section 11B-604.9, grab bars shall be installed in a horizontal position 18 inches minimum and 27 inches maximum above the finish floor measured to the top of the gripping surface. The height of the lower grab bar on the back wall of a bathtub shall comply with Section 11B-607.4.1.1 or 11B-607.4.2.1.SHEET A-1.1Cross reference accessible sink on the floor plan.Provide door schedule throughout the floor plan.Where Exit Tactile signage are referenced on plan, provide details.Cross reference new wall construction detail per “4/A-1” on floor plan.Provide wall legend to identify existing wall and proposed wall on floor plan.Provide wall dimensions throughout the floor plan.Provide an enlarged restroom detail with all accessibility dimensions on plan.Revise the following dimension for water closet.11B-604.2 Location. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 17 inches minimum to 18 inches maximum from the side wall or partition, except that the water closet shall be 17 inches minimum and 19 inches maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in Section 11B-604.8.2. Water closets shall be arranged for a left hand or right-hand approach.SHEET A2Show structural connection detail between soffit framing to roof structural members above.SHEET A2.1Cross reference soffit details on sheet “4/A-2”.Provide framing detail in lobby area where ceiling scheduling references a “hard-lid” ceiling.