HomeMy WebLinkAbout222616_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10190654
PROJECT ADDRESS:
2141 S Wright St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
M
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/2/2016
INITIAL REVIEW
9/16/2016
EXPIRATION
3/1/2017
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Sara Shishani
3.
TEL:
(714)746-7189
FAX:
VALUATION:
EMAIL:
sara@marvistaconstruction.com
FLOOD ZONE:X-0602320278J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.CBC Section 1015.2, Exit or exit access doorway arrangement. Required exits shall be located in a manner that makes their availability obvious. Exits shall be unobstructed at all times. Exit and exit access doorways shall be arranged in accordance with Sections 1015.2.1 and 1015.2.2.CBC Section 1015.2.1,Two exits or exit access doorways. Where two exits or exit access doorways are required from any portion of the exit access, the exit doors or exit access doorways shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the building or area to be served measured in a straight line between exit doors or exit access doorways. Interlocking or scissor stairs shall be counted as one exit stairway.Second Exit is required. Revise design as necessary.Minimum clear opening width on door “3” and “4” shall be 32 inches clear at 90 degrees from closing position. The existing 30 inches doors are too narrow.Provide exit signs along the corridor.Provide structural details for roof-screen attachments to the roofing structure.Show 60 inches diameter circle for turn-around space inside the toilet room on sheet AD1.0.