Loading...
HomeMy WebLinkAbout224063_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10191166 PROJECT ADDRESS: 2205 N Westwood Ave PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/20/2016 INITIAL REVIEW 10/27/2016 EXPIRATION 4/18/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Steve Tancredi 3. TEL: (714)231-8667 FAX: VALUATION: EMAIL: stancredi@robinrest.net FLOOD ZONE:X-0602320144JResubmit 2corrected sets of plans. The proposed revision is altering the conventional tie system for the roof framing elements. Provide a completeroof framing plans and full height cross sections through the building showing extend and supports forrafters, ridges, hips andvalleys. When the ceiling tie of each ridge board, hip, and valley member that are being altered and does not meet conventional design, roof elements must be redesigned to comply with CRC and or CBC code and provide construction details for their supports. Provide structural calculations and drawings prepared by a California Licensed Architect or Registered Civil Engineer for all structural work to be performed under the subject building permit application. See red marks on the plan. Resubmit the marked up set with revised plans for recheck.