HomeMy WebLinkAbout224082_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10191174 PROJECT ADDRESS: 1121 W Carlton Pl PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/15/2016 INITIAL REVIEW 11/28/2016 EXPIRATION 5/14/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Araceili Maciel 3. TEL: (714)285-1121 FAX: VALUATION: $32,777.00 EMAIL: aadrafting@msn.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Provide energy calcs to show compliance with title 24. Provide foundation or show adequacy of existing footing to support applied load at the end of beam FB2. Provide adequate shear walls at the new area affected by the addition including the new patio cover. Window 2 does not appear to meet the height criteria for emergency escape. Provide a legend for the smoke alarms and the Carbon monoxide detectors. Add a note to indicate they are interconnected and are hard wired. All toilet and shower need to comply with the low flush requirements see certification attached.