Loading...
HomeMy WebLinkAbout224914_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10191412 PROJECT ADDRESS: 1807 N Main St PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/21/2016 INITIAL REVIEW 12/8/2016 EXPIRATION 5/20/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Donnie DeWees 3. TEL: (714)850-7575 FAX: VALUATION:$168,701.00 EMAIL: ddewees@bundyfinkel.com FLOOD ZONE:X-0602320163J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Building Standards Code with local amendments.All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceProvide the following: - Provide a fully dimensioned site plan on each set of plans. - Disabled access compliance must be shown on the site plan. - provide a foundation plan and show the locations, dimensions, specifications, details, and other information for these: “A1 Arch Frame Footings”. Also, indicate the spacing for the canopy support.Show on the plans: - Occupancy Classification(s) - Type of Construction - Fire Sprinkler System It is the project designer’s/property owner’s responsibility to show compliance on the drawings with all applicable Federal and State Accessibility Standards.Provide structural calculations and drawings, stamped and signed by a California licensed architect or registered civil engineer for: - Structural support for these canopies. - provide spec. for the Canopy fabric and justify what does it mean “FABRIC VERY POROUS TO WIND”? I think a percentage of the fabric area shall be taken to resist the wind loads and the calculation shall take that area into the design of lateral load of the canopy support. - Submit calculation for anchor bolt design to support the loads of the canopy column.