HomeMy WebLinkAbout224340_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10191244 PROJECT ADDRESS: 512 S Euclid St Unit# . PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/31/2016 INITIAL REVIEW 11/16/2016 EXPIRATION 4/29/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Kevin Nguyen 3. TEL: (714)951-8540 FAX: VALUATION: $27,250.00 EMAIL: FLOOD ZONE: A-0602320252J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. The lateral design is not adequate, the back of the addition does not have any lateral resisting element, in addition, the addition is not configured to allow using cantilevered diaphragm. Detail 2 on three is referencing the wrong element, provide a section that shows the connection of the top of the post to the beams at the back of the patio. Label the grid on the plans in the same manner as the calcs or use the grid on the plans in your calcs. Beam FB3, provide calcs for the load combination where the load from the shear wall is in uplift, FB# does not have any dead load to resist uplift. Please clarify if the existing house is sprinklered. The original permit of the house show a fire sprinkler system.