Loading...
HomeMy WebLinkAbout225877_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10191668 PROJECT ADDRESS: 1421 W MacArthur Blvd Unit# A PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/19/2016 INITIAL REVIEW 12/28/2016 EXPIRATION 6/17/2017 RECHECKS: 1. 0118/2017 PROJECT APPLICANT CONTACT PERSON: 2. Ari Zamback 3. TEL: (714)227-1194 FAX: VALUATION:$53,850.00 EMAIL: arizambak@yahoo.com FLOOD ZONE:X-0602320258J The recheck of your plan was completed this morning, 01-18=2017; and the following items from the first plan check are not done/ completed. See the list below for item # 1, 2, 5, 6, 7, 8, 9, 10, 12, and 13. Please resubmit the plans to the City for recheck only after all the above items are corrected/ responded. APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceHand-activated door opening hardware shall be centered between 34” and 44” above the floor.See note # 33 on the sheet T-100. Please correct this note and resubmit for review and approval.Note on the drawings: “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding doors. See note # 33 on the sheet T-100. Please correct this note and resubmit for review and approval.Provide a continuous walking surface from each exit door to public way.Show compliance for the back exit door. See sheet A-100.Provide parking data on the site plan showing the total number of parking spaces provided, the number of disabled accessible spaces and the number of van accessible spaces, showing compliance with CBC Section 11B-208 and CBC Table 11B-208.2.One in every six accessible spaces, but not less than one, shall be served by an access aisle 8’-0” (96”) wide minimum and shall be designated van accessible.Where a single counter contains more than one transaction station, such as (but not limited to) a bank counter with multiple teller windows or a retail sales counter with multiple cash register stations, at least 5 percent, but never less than one, of each type of station shall be located at a section of counter that is at least 36” long and no more than 28 to 34” high.CBC Section 11B-222, Fitting and Dressing Rooms: - Where fitting or dressing rooms are provided for male or female customers, patients, employees, or the general public, 5 percent, but never less than one, of dressing rooms for each type of use in each cluster of dressing rooms shall be accessible. - show compliance with Section 11B-222.3 for the mirror. - show compliance with Section 11B-222.2 for coat hooks and shelves. - show compliance with Section 11B-803.See other red marks on the drawings. Please update the drawings and resubmit them for recheck along with the marked up set.