HomeMy WebLinkAbout223640_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10191022 PROJECT ADDRESS: 1805 W Berkeley St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/6/2016 INITIAL REVIEW 11/28/2016 EXPIRATION 4/4/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Mireya Valencia 3. TEL: (714)335-1549 FAX: VALUATION: $102,817.10 EMAIL: valenciajessica07@yahoo.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review. Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees. All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1).All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. In addition to other fees, a "Park Acquisition and Development Fee" in the amount shownbelow shall be required pursuant to a resolution of the City Council for the Recreation andCommunity Services Agency; net addition of ________ bedroom(s).Amount of $6,622.22; net addition of 5 bedroomsAmount of $5,952.18; net addition of 4 bedroomsAmount of $5,375.50; net addition of 3 bedroomsAmount of $4,006.57; net addition of 2 bedroomsAmount of $3,006.99; net addition of 1 bedroom Delete notes and details that do not apply to this project. Prior to the issuance of building permit(s), tract maps, parcel maps, lot line adjustments, public way abandonments, covenant, conditions and restrictions (CC&R's), etc., related to the subject project must be legally recorded with the County of Orange. Sheet A-1Engineer-On-Record shall provide signature at the Engineering seal.Add Balcony and its floor area under Project Data.Revise measurement of Fire Separation Distance on the site plan. Fire Separation Distance shall be measured perpendicular to the face of exterior wall.Under Scope of work, the square footing for total addition should be 1,090 square foot. Correct the number as necessary. Revise the Occupancy Group to “R3/ U” under Building Analysis.Revise the code edition to “2013” on Building Efficiency Standards under Applicable Codes. Sheet A-3Attic ventilation calculations indicate 7 dormer vents are required. Show dormer vents location on elevation drawings or on the roof plan. Sheet S-2Provide a structural connection detail at beam RB-5 where the beam supports roof rafter loads and ceiling joists load. See plan for location.Provide structural connection detail at beam FB-4 where stair-stringers connects to the floor level. Sheet SD2Detail 6: Specify material at the 1” standoff between wood post and concrete foundation.Detail 4: Provide a dimension for embedment length. The embedment shall be measure from the top of lower footing level on the left-side of the anchor bolt. See plan for red-marked location. Sheet EN-1Verify the existing water heater type. City record shows existing water heater is a “tank” type. Verify or revise efficiency value as necessary.