HomeMy WebLinkAbout225759_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10591624
PROJECT ADDRESS:
2222 S Center St
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
2/22/2017
INITIAL REVIEW
3/13/2017
EXPIRATION
8/21/2017
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Jose De Jesus Pena
3.
TEL:
(714)835-9114
FAX:
VALUATION: $6,500.00
EMAIL:
FLOOD ZONE: X-0602320259J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.
Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees.
All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
- Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.Provide a complete full-height section and details of stairway showing: (CRC R311.7)
- Maximum rise of 7 inches and minimum run (tread) of 11 inches.
- Minimum width of 36 inches.
- Framing (stringer, landing, etc.) size, bracing, connections, footings.
- Stairways positively anchored to the primary structure without using toe nails or nails subject to
withdrawal. Stairways within dwelling units and exterior stairways serving a dwelling unit shall have an illumination level of not less than 1 foot-candle measured at the center of the treads and landings. Exterior stairways serving a dwelling unit shall have an artificial light source located in the immediate vicinity of the top landing of the stairway. Dimension landings at top and bottom of stairs measured in the direction of travel not less than the stair width. Handrails are required on both on sides of a continuous run of treads or flight with four or more risers. Provide minimum 42” high Protective guards for decks and open sides of stairs and stair landing.Provide structural calculation and drawings stamped and signed by a California licensed Architect or Engineer.Please identify all structural members.Provide connection calculation and connection details of guards and/ or handrail on open side of stair , adequate to resist loads (200 lb) concentrated load at the top rail and 50 psf for intermediate rail.Make a note “ Smoke detector and carbon monoxide detector for all the units required, per CBC section 907.2.11.2.)