HomeMy WebLinkAbout228245_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10192324
PROJECT ADDRESS:
2413 S Fairview St
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/13/2017
INITIAL REVIEW
3/23/2017
EXPIRATION
9/9/2017
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Daniel Zaragoza
3.
TEL:
(626)488-9375
FAX:
VALUATION:$75,000.00
EMAIL:
dannydesigns09@yahoo.com
FLOOD ZONE:X-0602320258J
APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.Please return marked up set of drawings with corrections.All persons preparing plans, specifications, and instruments of service for others shall sign those plans, specifications and other instruments of service for others shall sign those plans, specifications and other instruments of service and all contracts therefore. This requirement applies to both exempt and non-exempt projects. Business and Professions Code Chapter 3, Division 3, Section 5536.1(a).The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Orange County Fire Authority approval on the corrected/final sets of drawings ((714)573-6100)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceThe accessible parking space and access aisles shall have slope not steeper than 1:48 in and direction per CBC Section 11B-502.4. Please modify details # 1, 3, 4, & 5/A1.0 to show compliance.Submitted plan is not clear. Provide details for ramps, curb ramps, the maximum slope of the curb ramps, flare sides of curb ramps and location of “ZERO CURB: on the plan.The running slope of walking surface shall not be steeper than 1:20 and the cross slope of the walking surfaces shall not be steeper than 1:48 per CBC Section 11B-403.2.3. Show compliance on the plan.Provide detail for detectable warnings to show compliance with CBC Section 11B-705.Curb ramps shall comply with CBC Section 11B-406. A level landing 4’ deep shall be provided at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface. Provide and show top landing for the proposed curb ramps.Accessible parking spaces serving a particular building shall be located on the shortest accessible route of travel from adjacent parking to an accessible entrance. Show the entrances for the existing buildings to ensure that a location of accessible stalls complies with the code.One in every six accessible spaces, but not less than one, shall be served by an access aisle 8’-0” (96”) wide minimum and shall be designated van accessible as required by Section 11B-208.2.4. Provide 2 van accessible stalls.See other red marks on the drawings. Please resubmit the marked up plans to City for recheck.