HomeMy WebLinkAbout229990_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10192903 PROJECT ADDRESS: 2 E MacArthur Pl Unit# 300 PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: I A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/8/2017 INITIAL REVIEW 5/18/2017 EXPIRATION 11/4/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Dale Rask 3. TEL: (909)390-8392 FAX: VALUATION:$25,000.00 EMAIL: drask@trlsystems.com FLOOD ZONE:X-0602320278JAPPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSPlease indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.This review does not include electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings (949573-6108) - Police Department approval on the corrected/final set of drawings (647-5840) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceProvide missing drawings to show compliance with followings incompliance with California Building Code, 2016 CBC:Section 1010.1.9.7 Delayed egress101.1.9.8 Sensor release of electronically locked egress doors10110.1.9.12 Access- controlled elevator lobby doors in high-rise office buildingsIdentify location of type device to be installed on the drawings and provide elevation/s of control device at height of 48” maximum from floor and required accessibility clearance for devise. When applicable, plans shall indicate how required structural and fire resistive integrity will be maintained where a penetration will be made for electrical, and communication conduits, and similar systems. CBC Section 106.1.1 and CBC Chapter 7. Note on the plans the ICC Research Report number, U.L. number, State Fire Marshal number for cloaking of permitted penetrations.