Loading...
HomeMy WebLinkAbout231437_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10193318 PROJECT ADDRESS: 1000 W MacArthur Blvd Unit# 65 PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/20/2017 INITIAL REVIEW 7/24/2017 EXPIRATION 12/17/2017 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. George Martinez 3. TEL: (949)678-1006 FAX: VALUATION: $6,000.00 EMAIL: George@mccservices-socal.com FLOOD ZONE: X-0602320258J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.Reference calculations Sheet 14 and drawings Sheet D-1, detail # 16, Revise detail to show positive connection for Guards, (10) d nails at post base. Show spacing of guard railing to less than 4” for 2nd floor. Provide detail of the guard showing that a 4” diameter sphere shall not pass through any opening in the guard. (CRC R312.3)