HomeMy WebLinkAbout232725_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10193708 PROJECT ADDRESS: 1901 E Carnegie Ave Unit# A PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/2/2017 Dispensary Ti INITIAL REVIEW 9/11/2017 EXPIRATION 1/29/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jonathon Weber 3. TEL: (714)655-5925 FAX: VALUATION:$211,558.00 EMAIL: jweber@adcollaborative.com FLOOD ZONE:X-0602320279J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please refer to mark up set of drawings for additional plan check comments. Return marked up set of drawings with corrections.Resubmit 3corrected sets of plans.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceNote on the floor plan the use and occupancy load of each room and/or area. Relate each use to a CBC Table 1004.1.2 of 2016 CBC. Please refer to red marks on the drawings. Table 1006.3.2 (2) For Buildings With One Exit:Maximum HeightMaximum OccupantsOf Building(Or Dwelling Units) Occupancy Above Grade PlanePer Floor And Travel Distance B, , M, 1 Story 49 occupants and 75’ travel distanceTable 1017.2Exit Access Travel Distance: OCCUPANCYWITHOUT SPRINKLERWITH SPRINKLERSYSTEM (feet)SYSTEM (feet) M,200250b B200300cExit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more.Show/note ventilation requirements on the plans in accordance with the CBC and California Mechanical Code (CMC) requirements for each type of use. Note on drawings:- Provide mechanical ventilation for each area/room in accordance with the 2016 California Mechanical Code.Note on drawings:Show/note LIGHTING requirements on the plans in accordance with CBC and California Electrical Valuation of proposed project is calculated as $211558.00. A minimum of 20% of valuation of construction is required to be spent towards providing disabled access in the priority order based on Section 11B-204 of 2016 CBC Drawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC 11-B, Division 2. - An accessible entrance - An accessible route to the altered area - Accessible restrooms - Accessible telephone (if any) - Accessible drinking fountains, and - Parking, signage and alarmsProvide enlarged and dimensioned floor plan of each toilet room including elevations of existing toilet room and show compliance with Sections 11B-603 and 11B-604 of 2016 CBC. Provide drawings to show compliance with following items;All doors require a level floor landing on each side Provide typical door threshold details (1/2” max threshold) and when applicable provide details of change in floor covering materialThe width of the level area on the side to which the door swings shall extend 24” past the strike edge of the door for exterior doors and 18” past the edge for interior doors. All building entrances that are accessible to and usable by persons with disabilities shall be identified with a least one standard sign and with an additional directional signs, as required, to be visible to persons along approaching pedestrian ways.Hand-activated door opening hardware shall be centered between 34” and 44” above the floor. Latching and locking doors that are hand activated and which are in a path of travel shall be operable with a single effort by lever-type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Locked exit doors shall operate as above in egress direction. Note on the drawings: “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding doors. Provide specifications for doors hardware (i.e., lever type, push-pull panic, etc.) to comply with disabled access requirements. Revise door schedule to include accessibility compliance. All building entrances that are accessible to and usable by persons with disabilities shall be identified with a least one standard sign and with an additional directional signs, as required, to be visible to persons along approaching pedestrian ways.Required the bottom 10” of all doors except automatic and sliding shall have a smooth uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition.Tactile exit signs shall be required at the following locations: Show locations on each applicable signage the drawings including the height:(11B-703.4.1 and 703.6, 2016 CBC) - Each grade-level exterior exit door shall be identified by a tactile exit with the word “EXIT.” - Each exit access door from an interior room or area to a corridor or hallway, which is required to have a visual exit sign, shall be identified by a tactile exit sign with the words “EXIT ROUTE.”- Each exit door through a horizontal exit shall be identified by a sign with the words “TO EXIT.”Clarify path of accessible path of travel on the drawings and indicate slope (5% max) and cross slop (2% max.) on the drawings. Relocate location of accessible parking stalls to near building entrance. Please refer to red marks on the drawings. Provide truncate domes. If a walk crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings or other elements (at zero curb) between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning which is 36” wide. Detectable Warning Product Approval. Only approved Division of the State Architect, Access Compliance (DSA/AC) approved detectable warning products and directional surfaces shall be installed in accordance with CBC Section 705.1, 2016 CBC.Sales counters to comply with 11B-227.3, one of each type eachfor client and employee use to be accessible as below. - Provide 36” length counter. - Provide a minimum 30” x 48” wheelchair clear floor space. - Provide knee space at tables at least 27” high, 30” wide and 19” deep for forward approach. - Provide height of tables between 28” – 34” from the floor ground.Show location of drinking fountains on the floor plan, drinking fountains serving the area of new work shall be accessible (High and low). Please refer to Table 422.1 of CPC for exceptions and show compliance on the drawings.Provide parking data on the site plan showing the total number of parking spaces is required and provided for proposed project and show required number of disabled accessible spaces and the number of van accessible spaces on the drawings. Surface slopes of accessible parking spaces shall be the minimum possible and shall not exceed 1 unit vertical to 48 units horizontal (2% slope) in any direction.. Additional plan check comments may apply to this project.