HomeMy WebLinkAbout234201_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10194207
PROJECT ADDRESS:
1000 E Santa Ana Blvd
PLAN CHECK ENGINEER:
Chehade, NabilTEL:714
647-5848FAX:714
647-5897
TYPE OF CONSTRUCTION:
III A
OCCUPANCY CLASSIFICATION(S):
A-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/19/2017
INITIAL REVIEW
10/13/2017
EXPIRATION
3/18/2018
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Suzi Furjanic
3.
TEL:
(714)647-4241
FAX:
VALUATION:$54,000.00
EMAIL:
sfurjanic@santa-ana.org
FLOOD ZONE:X-0602320163J
APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2 corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)( check with Rubin prior to submittal to fire)
- Public Works Agency approval (647-5039)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSpecify the type of construction and occupancy group of the building on the plans; indicate if the building if sprinklered or not.North bath, provide a 5’ landing in front of the accessible stall.( both sides)Provide spec for the stall door handle. Please note a handle is needed on both sidesDimension strike edge clearance next to the entrance door to the bathroom.Provide a dimension that shows a 48” min. clear in front of the toilet.Dimension the distance from the wall to the stall door hinge to be a maximum of 4”.Provide a min. 5 ft. landing in front of the entry doors to the bathrooms.( Dimension)This is a 1-hour rated building, any penetrations in a rated wall has to comply with the penetration provisiond of the CBC for rated construction. Identify all penetration and the size and type of pipe.