HomeMy WebLinkAbout235600_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10194632 PROJECT ADDRESS: 804 W Washington Ave PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/31/2017 INITIAL REVIEW 11/9/2017 EXPIRATION 4/29/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. William Lushbaugh 3. TEL: (949)584-2166 FAX: VALUATION:$12,000.00 EMAIL: blushgaugh@aol.com FLOOD ZONE:X-0602320144JAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The scope of work for this project is to install 3/8” plywood on the front walls of existing garages plus, installing anchor bolts and holdowns at each side of garage opening per details shown on sheet SD-1 of the drawings. Sine it is a voluntary upgrade, a building permit can be issue for this work. However, a note needs to be added to the cover sheet to indicate “THIS IS NOTA full “SEISMIC UPGRADE” of the building.In order to comply with seismic upgrade of 2016 California Building Code, a full structural analysis and full construction details of this 60+ year old building need to be provided. I don’t that this is what the applicant is looking for. So, the above mentioned note needs to be added to the cover sheet of these drawings. This review does not include electrical work. Separate plan, application, fee, plan check, and permit may be required for electrical work. Call 647-5800 for information.] The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Sill plates supporting shear walls with lateral loads greater than 350 pounds/foot require a 3-inch nominal or greater member. Note on the detail 5/SD-1 that foundation anchor bolts in walls shall have an approved plate washer under each nut; and the nuts shall be tightened just prior to covering the wall framing. Plate washers a minimum of 3 inch by 3 inch by 0.229 inch thick shall be used on each bolt.