HomeMy WebLinkAbout231997_3_Corrections.docx PLAN CHECK NO: 10193486/87 PROJECT ADDRESS: 1718 W Highland St PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/11/2017 INITIAL REVIEW 7/20/2017 EXPIRATION 1/7/2018 RECHECKS: 1. 10/24/2017 PROJECT APPLICANT CONTACT PERSON: 2. Eduardo Arazon 3. TEL: (951)961-6084 FAX: VALUATION:$57,200.00 EMAIL: agconcreteconstruction@gmail.com FLOOD ZONE:X-0602320257J The recheck of your drawing was completed this morning, 10/24/2017; and the following items from the first plan check list are not done/ completed at this time. See the list below for item # 14 & 23. Plans are placed at the plan check counter for your convenience.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. On sheet G-1, the code references shall be updated to 2016 codes. On sheet G-1, the water flow for the lavatory faucets shall be changed from 1.5 to 1.2 GPM. All the items that are crossed off by Planning Division from the building permit application shall be incorporated into the new set of plans. See sheet C-1 for these crossed off items. Make sure that proposed addition is not eliminating any of existing under floor and the attic vents. On sheet S-1, the wood shall have a distance of 8” away from the finish grade. See red marks on this sheet. The plywood thickness for the Shear wall on the plans does not match the structural calculation. Provide the missing details and foundations as marked on the plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Projections, including eaves, shall have one-hour fire-resistive construction on the underside when the distance to property line is within 2 to 5 feet per CRC Section R302.1 (1). Show compliance on the plans.Dimension roof overhangs showing compliance with CRC Section R302.1. Show location of minimum 20x30-inch attic access with 30-inch minimum headroom in the proposed addition. Wall covering shall be cement plaster, tile or approved equal to 72 inches above drain at showers or tub with showers. Materials other than structural elements shall be moisture resistant. Glass enclosure doors and panels must be labeled Category II. Swing door outward. Show the location(s) of hard-wired smoke detector(s) with a battery back up in each sleeping room and at a point centrally located in the corridor or area giving access to each sleeping area. Show location of Carbon monoxide on the plans. Provide full height cross sections through the building showing framing, interior/exterior sheathing, plate heights, insulation, foundation, finish grade, etc. The City has encountered a large number of inspection problems arising from a lack of specific framing details. The following listed items are required to be shown on the plans: -All plumbing walls are to be framed with a minimum of 6" studs. -Permissible notching and boring of joists are to be shown on the plans and shall not exceed CRC allowances. -Notching of exterior and bearing/nonbearing walls shall not exceed 25%/40% respectively. Bored holes in bearing/nonbearing walls shall not exceed 40%/60% respectively. In no case shall the edge of the bored hole be nearer than 5/8 inch to the edge of the stud. -All framed buildings which are required to be designed by an engineer or architect must be signed prior to submission into plan check -Show location(s) and provide typical construction details. The residence shall conform to the State Energy Conservation Standards. Submit forms and calculations for review and blueprint the final forms on the plans. -Signed Energy Efficiency Documents must be printed on the plans. -Also, submit 2 copies of signed Energy Efficiency calculations. -The permit applicant shall be responsible for obtaining an energy plan check from a consultant who is qualified to perform an energy efficiency analysis in accordance with the California Code of Regulations (CCR), Title 24, Part 1 (Administration) and Part 6 (2016 California Energy Code). The plan check consultant must sign documentation certifying that a thorough, competent review has been performed on behalf of the Enforcement Agency. -The corrected/final drawings shall have the required energy efficiency compliance documentation with completed signature blocks filed on the plans. -The energy plan check consultant must sign documentation forms on behalf of the Building Safety Division. -Refer to the attached public handouts titled “Energy Efficiency Compliance” and “Energy Efficiency Compliance Documentation”.On the drawings, provide Nailing Schedule. Roof ridge board shall not be smaller than the rafter they support. Note on the plans: "Roof diaphragm nailing to be inspected before covering. Face grain of plywood shall be perpendicular to supports." Provide a weep screed for stucco at the foundation plate line a minimum of 4 inches above the earth or 2 inches above paved areas. Note on the plans that hold-down connector bolts into wood framing require approved plate washers; and hold-downs shall be tightened just prior to covering the wall framing. Note on the plans that foundation anchor bolts in walls shall have an approved plate washer under each nut; and the nuts shall be tightened just prior to covering the wall framing. Plate washers a minimum of 3 inch by 3 inch by 0.229 inch thick shall be used on each bolt. See other red marks on the drawings. Please resubmit the marked up set with new and revised plans for recheck.